Difference between revisions of "PAB"
(Created page with "The PAB (... Blocks) define sets of conditions for monitored quantities (current, voltage, S0 pulses etc.). Based on these conditions, various rules can be set. Rules can perf...") |
|||
Line 1: | Line 1: | ||
− | The PAB ( | + | The PAB (Power Analyzing Block) define sets of conditions for measured variables (current, voltage, S0 pulses etc.). Various rules can be set based on these conditions. Rules can perform actions such as sending alarm to the Cloud service, restarting outputs, etc. |
− | The PAB output is also available for use in selected protocols. | + | The PAB condition output is also available for use in selected protocols. |
− | + | There are two types of PAB available: | |
− | 1) RANGE - | + | 1) RANGE - Evaluation YES/NO (true/false) |
− | 2) ZONE - | + | 2) ZONE - Evaluation using specified intervals |
− | + | Each type uses specific variables and is described in detail below. | |
− | + | PABs can work with the specified quantities: | |
− | * | + | * Current: OUTPUTS/1/CURRENT **[mA]** |
− | * | + | * Load: OUTPUTS/8/LOAD **[W]** |
− | * | + | * Energy: OUTPUTS/4/POWER **[Wh]** |
− | * | + | * Output no. 1 state: OUTPUTS/1/STATE **[int 0/1]** |
− | + | General structure for defining a variable is: `<INPUT/OUTPUT>/ID/<monitored variable>` | |
− | ## PAB | + | ## PAB - RANGE |
− | + | True/False-based evaluation. If the monitored value is in specified interval for a time period defined in `timeHysteresis`, PAB evaluates as `True`. Otherwise it evaluates as `False`. | |
− | ### | + | ### Structure |
− | | | + | {| class="wikitable" |
− | | - | + | |- |
− | | type | RANGE | | + | ! Variable |
− | | source | OUTPUTS/**x**/(LOAD/CURRENT/POWER) <br> INPUTS/**x**/STATE | | + | ! Value |
− | | timeHysteresis | int | [s] | + | ! Description |
− | | lowerBound | int | | + | |- |
− | | upperBound | int | | + | | type |
+ | | RANGE | ||
+ | | PAB type | ||
+ | |- | ||
+ | | source | ||
+ | | OUTPUTS/**x**/(LOAD/CURRENT/POWER) <br> INPUTS/**x**/STATE | ||
+ | | The monitored variable. **x** indicates input / output number. | ||
+ | |- | ||
+ | | timeHysteresis | ||
+ | | int | ||
+ | | [s] Monitored value must be present in defined interval for amount of time defined here. Eg: If the time hysteresis is equal to 5, monitored value must be within a defined interval for at least 5s. Only then it will be evaluated. | ||
+ | |- | ||
+ | | lowerBound | ||
+ | | int | ||
+ | | lower bound of the monitored value | ||
+ | |- | ||
+ | | upperBound | ||
+ | | int | ||
+ | | upper bound of the monitored value | ||
+ | |} | ||
− | ## PAB | + | ## PAB - ZONE |
− | + | Zone-based evaluation. 1 or more zones can be set. Zones are divided using the values specified in the `thresholds` variable. | |
− | + | Monitored value must be present in defined interval for amount of time defined here. The PAB condition is evaluated as a number (integer) equal to the interval order. Eg. At two specified intervals, the PAB value can be 0, 1, or 2. | |
### Struktura | ### Struktura |
Revision as of 15:47, 19 October 2021
The PAB (Power Analyzing Block) define sets of conditions for measured variables (current, voltage, S0 pulses etc.). Various rules can be set based on these conditions. Rules can perform actions such as sending alarm to the Cloud service, restarting outputs, etc. The PAB condition output is also available for use in selected protocols.
There are two types of PAB available: 1) RANGE - Evaluation YES/NO (true/false) 2) ZONE - Evaluation using specified intervals Each type uses specific variables and is described in detail below.
PABs can work with the specified quantities:
* Current: OUTPUTS/1/CURRENT **[mA]** * Load: OUTPUTS/8/LOAD **[W]** * Energy: OUTPUTS/4/POWER **[Wh]** * Output no. 1 state: OUTPUTS/1/STATE **[int 0/1]**
General structure for defining a variable is: `<INPUT/OUTPUT>/ID/<monitored variable>`
- PAB - RANGE
True/False-based evaluation. If the monitored value is in specified interval for a time period defined in `timeHysteresis`, PAB evaluates as `True`. Otherwise it evaluates as `False`.
- Structure
Variable | Value | Description |
---|---|---|
type | RANGE | PAB type |
source | OUTPUTS/**x**/(LOAD/CURRENT/POWER) INPUTS/**x**/STATE |
The monitored variable. **x** indicates input / output number. |
timeHysteresis | int | [s] Monitored value must be present in defined interval for amount of time defined here. Eg: If the time hysteresis is equal to 5, monitored value must be within a defined interval for at least 5s. Only then it will be evaluated. |
lowerBound | int | lower bound of the monitored value |
upperBound | int | upper bound of the monitored value |
- PAB - ZONE
Zone-based evaluation. 1 or more zones can be set. Zones are divided using the values specified in the `thresholds` variable. Monitored value must be present in defined interval for amount of time defined here. The PAB condition is evaluated as a number (integer) equal to the interval order. Eg. At two specified intervals, the PAB value can be 0, 1, or 2.
- Struktura
| Proměnná | Hodnoty | Popis |
| ------ | ------ | ------ |
| type | ZONE | typ PAB |
| source | OUTPUTS/**x**/(LOAD/CURRENT/POWER)
INPUTS/**x**/STATE | Měřená hodnota, kterou sledujeme. **x** udává číslo vstupu/výstupu.|
| timeHysteresis | int | [s] Časový interval, ve kterém se musí nacházet sledovaná hodnota. Př.: Pokud je hystereze rovná 5, musí se sledovaná hodnota nacházet v definovaném intervalu (intervalech) alespoň 5s. Až následně dojde k jejímu vyhodnoceí. |
| thresholds | list[int] | seznam spodních hranic intervalů pro přechod mezi zónami
- Příklady
Podmínka se vyhodnotí jako **true** okamžítě, jakmile se hodnota proudu objeví mezi 100 a 200 mA. ``` {
"type": "RANGE", "source": "OUTPUTS/1/CURRENT", "lowerBound": 100, "upperBound": 200, "timeHysteresis": 0
} ``` Podmínka se vyhodnotí jako **true** v případě, že se hodnota proudu bude nacházet mezi 100 a 200 mA po dobu 5s. ``` {
"type": "RANGE", "source": "OUTPUTS/1/CURRENT", "lowerBound": 100, "upperBound": 200, "timeHysteresis": 5
} ```
Podmínka se vyhodnotí dle stanovených zón v případě, že se hodnota proudu bude nacházet v jedné ze zón po dobu 10s. Př.: Pokud bude proud 130mA po dobu alespoň 10s, vyhodnotí se podmínka jako 2 (číslo zóny). ``` {
"type": "ZONES", "source": "OUTPUTS/2/CURRENT", "thresholds": [ 50, 100, 150, 200 ], "timeHysteresis": 10
} ```