Difference between revisions of "Function devices.system.resetCumulativeConsumption()"
Jump to navigation
Jump to search
Line 2: | Line 2: | ||
Resets the energy counter for the outlet. To read the counter, use [[Number devices.system.output1 cumulatedConsumption|devices.system.output1_cumulatedConsumption]]. | Resets the energy counter for the outlet. To read the counter, use [[Number devices.system.output1 cumulatedConsumption|devices.system.output1_cumulatedConsumption]]. | ||
− | <b>Warning!</b><br>Note the name inconsistency: <u>output1</u>_cumulat<u>ed</u>Consumption and resetCumulat<u>ive</u>Consumption{<u>output=1</u>}. | + | <b>Warning!</b><br>Note the name inconsistency: <i><u>output1</u>_cumulat<u>ed</u>Consumption</i> and <i>resetCumulat<u>ive</u>Consumption{<u>output=1</u>}</i>. |
<i>nil</i> devices.system.resetCumulativeconsumption{<u>config</u>} | <i>nil</i> devices.system.resetCumulativeconsumption{<u>config</u>} |
Revision as of 10:07, 15 April 2017
Resets the energy counter for the outlet. To read the counter, use devices.system.output1_cumulatedConsumption.
Warning!
Note the name inconsistency: output1_cumulatedConsumption and resetCumulativeConsumption{output=1}.
nil devices.system.resetCumulativeconsumption{config}
Parameters
table config
- number output outlet where to reset the counter (1 to 4)
Return value
nil
Usage
-- reset the counter for output No.1 devices.system.resetCumulativeConsumption{output=1}
See also
- devices.system.output1 cumulatedConsumption - reads the energy counter