Number devices.system.output1 consumption: Difference between revisions
Jump to navigation
Jump to search
No edit summary |
|||
| (4 intermediate revisions by the same user not shown) | |||
| Line 1: | Line 1: | ||
{{DISPLAYTITLE: | {{DISPLAYTITLE:number devices.system.output1_consumption}} | ||
Returns the power (U × I) consumed from the outlet (in Watts). <b>The property is read only!</b> | Returns the power (U × I) consumed from the outlet (in Watts). <b>The property is read only!</b> | ||
electric power of outlet 1 | <b>electric power of outlet 1</b><br><i>number</i> <code>devices.system.output1_consumption</code> | ||
electric power of outlet 2 | |||
<b>electric power of outlet 2</b><br><i>number</i> <code>devices.system.output2_consumption</code> | |||
electric power of outlet 3 | |||
electric power of outlet 4 | <b>electric power of outlet 3</b><br><i>number</i> <code>devices.system.output3_consumption</code> | ||
<b>electric power of outlet 4</b><br><i>number</i> <code>devices.system.output4_consumption</code> | |||
=== Value === | === Value === | ||
| Line 17: | Line 20: | ||
=== Usage === | === Usage === | ||
-- turn off outlet No.1 if the current in 240 V grid exceeds 4 A. | -- turn off outlet No.1 if the current in 240 V grid exceeds 4 A. | ||
if devices.system. | if devices.system.output1_consumption>980 then | ||
system.devices.SetOut(1,false) | system.devices.SetOut(1,false) | ||
end | end | ||
Latest revision as of 18:29, 18 April 2017
Returns the power (U × I) consumed from the outlet (in Watts). The property is read only!
electric power of outlet 1
number devices.system.output1_consumption
electric power of outlet 2
number devices.system.output2_consumption
electric power of outlet 3
number devices.system.output3_consumption
electric power of outlet 4
number devices.system.output4_consumption
Value
Actual power consumption in Watts.
Usage
-- turn off outlet No.1 if the current in 240 V grid exceeds 4 A. if devices.system.output1_consumption>980 then system.devices.SetOut(1,false) end
See also
- devices.system.SetOut() to change the state of the outlet