Difference between revisions of "Watchdog"

From wiki.netio-products.com
Jump to navigation Jump to search
 
(One intermediate revision by the same user not shown)
Line 9: Line 9:
 
* Watchdog '''Fail = TRUE''' = ping answer '''not received'''
 
* Watchdog '''Fail = TRUE''' = ping answer '''not received'''
  
Once network connection is not active the watchdog is not in operation. To detect these stater use Connectivity events in RULES.  
+
<sup><code>FW 4.0.0+</code></sup>Once network connection is not active the watchdog is not in operation. To detect these stater use Connectivity events in RULES.  
  
 
== Structure ==
 
== Structure ==
Line 42: Line 42:
 
| int
 
| int
 
| Maximum number of restarts when an error condition is declared. After this limit is reached, the WatchDog remains in an <code>FAIL=TRUE</code> state until the next successful ping.
 
| Maximum number of restarts when an error condition is declared. After this limit is reached, the WatchDog remains in an <code>FAIL=TRUE</code> state until the next successful ping.
If set to 0, WatchDog will restart after each FAIL=TRUE is declared (This can cause indefinite restarts when the ping remains unsuccessful).
+
If set to 0, WatchDog will restart output (trigger rule) after each FAIL=TRUE is declared and not only if FAIL status is changed (This can cause indefinite restarts when the ping remains unsuccessful).
  
If set to -1, WatchDog will NOT restart itself again. E.g. it remains in FAIL=TRUE state after it is declared.
+
If set to -1, WatchDog will restart output (trigger rule) only once and then remains in FAIL=TRUE state until next successful ping.
 
|-
 
|-
 
| startDelay
 
| startDelay

Latest revision as of 19:01, 19 June 2023

Watchdog diagram

Watchdog is a function periodically pinging to one defined IP address or URL. It's periodically checking reply from defined IP device by ping (ICMP). You can monitor physical presence of the IP device or Internet connectivity. You can use several WatchDog functions in parallel.

Based on each Watchdog state one or several RULEs can be executed. Each Rule can perform several actions (Set Output, Short Off (restart) output, Toggle output or send Alarm state to the NETIO Cloud service. Based on this Alarm state can NETIO Cloud send email to defined recipient. All Watchdogs are listed in the JSON protocol wit their current states. It can be used by 3rd party software.

Each Watchdog function state is the FAIL variable.

  • Watchdog Fail = FALSE = ping answer is OK
  • Watchdog Fail = TRUE = ping answer not received

FW 4.0.0+Once network connection is not active the watchdog is not in operation. To detect these stater use Connectivity events in RULES.

Structure

Variable Value Description
target IP / URL Monitored address
pingInterval int [s] Time interval between pings
timeout int [s] Time waiting for answer
maxTimeouts int Number of failed pings required to evaluate to FAIL=TRUE
timeToReboot int [s] Time the Watchdog waits after announcing an error condition before starting a new cycle
maxRestarts int Maximum number of restarts when an error condition is declared. After this limit is reached, the WatchDog remains in an FAIL=TRUE state until the next successful ping.

If set to 0, WatchDog will restart output (trigger rule) after each FAIL=TRUE is declared and not only if FAIL status is changed (This can cause indefinite restarts when the ping remains unsuccessful).

If set to -1, WatchDog will restart output (trigger rule) only once and then remains in FAIL=TRUE state until next successful ping.

startDelay int Starting delay in seconds at watchdog startup.(Enable or device power up)FW 4.0.0+

Example:

{
 "target": "192.168.101.130",
 "pingInterval": 5,
 "timeout": 1,
 "maxTimeouts": 2,
 "timeToReboot": 10,
 "maxRestarts": -1,
 "startDelay": 0
}