Difference between revisions of "Function devices.system.resetCumulativeConsumption()"
Jump to navigation
Jump to search
Line 4: | Line 4: | ||
<b>Warning!</b><br>Note the name inconsistency: <i><u>output1</u>_cumulat<u>ed</u>Consumption</i> and <i>resetCumulat<u>ive</u>Consumption{<u>output=1</u>}</i>. | <b>Warning!</b><br>Note the name inconsistency: <i><u>output1</u>_cumulat<u>ed</u>Consumption</i> and <i>resetCumulat<u>ive</u>Consumption{<u>output=1</u>}</i>. | ||
− | <i>nil</i> <b>devices.system.resetCumulativeconsumption</b> | + | <i>nil</i> <b>devices.system.resetCumulativeconsumption</b>(<code>config</code>) |
=== Parameters === | === Parameters === | ||
− | <i>table</i> < | + | <i>table</i> config{<code>number</code>} |
* <i>number</i> <code>output</code> outlet where to reset the counter (1 to 4) | * <i>number</i> <code>output</code> outlet where to reset the counter (1 to 4) | ||
Latest revision as of 22:07, 19 April 2017
Resets the energy counter for the outlet. To read the counter, use devices.system.output1_cumulatedConsumption.
Warning!
Note the name inconsistency: output1_cumulatedConsumption and resetCumulativeConsumption{output=1}.
nil devices.system.resetCumulativeconsumption(config
)
Parameters
table config{number
}
- number
output
outlet where to reset the counter (1 to 4)
Return value
nil
Usage
-- reset the counter for output No.1 devices.system.resetCumulativeConsumption{output=1}
See also
- devices.system.output1_cumulatedConsumption - reads the energy counter